Long Pass Filters (LPF)

Optical Filters for Gas Detection

Features
The Infrared Bandpass Filter designed for gas detection equipment primarily uses monocrystalline silicon as its substrate, with alternating layers of germanium (Ge) and zinc selenide (ZnSe) thin films deposited on its surface. It is suitable for infrared sensing elements and related optical detection systems.
Customized infrared bandpass filters with specified wavelength ranges are available according to customer requirements. The filters feature high blocking performance, high transmittance, excellent coating adhesion, good surface cleanliness, and low optical absorption. They effectively select infrared signals within the target wavelength range and maintain stable, reliable optical performance, meeting the application requirements of various infrared sensing and gas detection devices.
Applications
Temperature Sensing Elements
Gas Detectors
Optical Detectors
Add Inquiry (0)

Optical Specifications

AOI Wavelength Range Optical Specifications
AOI:0° 1.5~5.5um 1.5~2.6umT<1%, 2.7~3.1um T>90%, 3.2~5.5um T<1%
AOI:0° 1.5~7.5um 1.5~3.4um T<1%, 3.6~4.9um T>90%, 5.1~7.5um T<1%
AOI:0° 0.38~12um CWL3.4±0.04um, Tpeak>85%; FWHM: <0.15um; 0.38~12umT<1%
AOI:0° 0.38~12um CWL4.25±0.04um, Tpeak>85%; FWHM: <0.18um; 0.38~12umT<1%

Environmental Reliability Testing

Items Test Conditions
Coating Adhesion Test A cross-hatch test is performed, followed by a tape pull test using 3M 610 tape. No coating peeling or delamination is permitted.
Damp Heat Test 50 ± 2℃ / 90 – 95% RH for 24 hours. The coating must remain intact after testing.
Thermal Shock Test The sample is maintained at -60 ± 2℃ and +70 ± 2℃ for 2 hours at each temperature. After testing, the sample is allowed to rest at room temperature (16–32℃). The coating must remain intact with no visible abnormalities.
Water Resistance Test The sample is immersed in distilled water at room temperature (16–32℃) for 24 hours. The coating must remain intact after testing.
TOP